ѓ Faulty wiring. ѓ Weight sensor faulty. ѓ Main board faulty. Drain filter clogged (drain phase too long) ѓ Drain filter clogged/dirty. ѓ Unbalanced load ѓ Final spin phases skipped. Reset ѓ A.D.L. 10 / 2010 Aqua control system intervention ѓ Water leaks onto base frame. ѓ Aqua control device faulty. ѓ Tap closed. ѓ Water fill pressure too low. Description ѓ Faulty wiring. ѓ Solenoid valve faulty/blocked. ѓ Circuit board faulty ѓ Excessive detergent dosing. ѓ Drain hose kinked/blocked. ѓ Drain filter clogged/dirty. ѓ DSP sensor faulty. ѓ Transmission belt broken. ѓ Main circuit board faulty. ѓ Faulty wiring. ѓ DSP sensor faulty. ѓ Transmission belt broken. ѓ Main circuit board faulty.
ѓ Faulty wiring. No drum position signal made. No signal from the DSP during motor activation. Electronically controlled valve blocked with operating flowmeter Problems with weight sensor (no signal or outside the limits) Water fill pressure too low, no signal from flowmeter and electronically controlled valve is open Overdosing of detergent (too much foam during drain phases) ALARM CODE EA1 EA6 EC1 EC3 EF1 EF2 EF3 EF4 EF5 EF6 ALARM CODE Action Description Possible fault Reset Machine status EA1 No drum position signal made. DSP sensor faulty. Transmission belt broken. Main circuit board faulty. Faulty wiring.
Drum positioning cycle cancelled START/RESET EA6 No signal from the DSP during motor activation. DSP sensor faulty. Transmission belt broken. Main circuit board faulty. Faulty wiring. Cycle paused. START RESET EC1 Electronically controlled valve blocked with operating flowmeter Faulty wiring. Solenoid valve faulty/blocked. Circuit board faulty Cycle stops with door locked Drain pump continues to operate (5 min. on, then 5 min. off etc.) RESET EC3 Problems with weight sensor (no signal or outside the limits) Faulty wiring. Weight sensor faulty. Main board faulty. ---------------- START/RESET EF1 Drain filter clogged (drain phase too long) Drain filter clogged/dirty.
Drain hose blocked/kinked/too high. Warning displayed at the end of cycle. START/RESET EF2 Overdosing of detergent (too much foam during drain phases) Excessive detergent dosing. Drain hose kinked/blocked. Drain filter clogged/dirty. Warning displayed after 5 attempts or by the specific LED. RESET EF3 Aqua control system intervention Water leaks onto base frame. Aqua control device faulty. Appliance drains ON/OFF RESET EF4 Water fill pressure too low, no signal from flowmeter and electronically controlled valve is open Tap closed. Water fill pressure too low. ---------------- RESET EF5 Unbalanced load Final spin phases skipped.
---------------- START/RESET EF6 Reset If it continues, replace the main board ---------------- ----------------