EPSON — ~TA

~TA [Name] Adjust tear-off position [Format] ~TA d [Function]  Sets the value to adjust the tear-off position.  Parameter d must be specified as a numerical value. An example setting a positive value and an example setting a negative value are shown below.  If you want to set 20, set ~TA20.  If you want to set -20, set ~TA-20. [Response] None [Reference] Related commands: None [Note] The ^JUS command is required to save settings to the non-volatile memory of the printer unit. Please refer to the “^JU” command section for details.

[Usage example] An example of sending data that sets the value to adjust the tear-off position and saves settings to the non-volatile memory of the printer unit is shown below. ~TA20 1. Sets the value to adjust the tear-off position to 20 [dot]. ^XA ^JUS 2. Saves the setting to non-volatile memory. ^XZ ESC/Label Command Reference Guide Rev. L Page 201 Parameters Description Definition range d Value to adjust tear-off position [dot] -9999 ≤ d ≤ 9999