U.S. Army FM 34-54 — Appendix I

Downloaded from https://www.everyspec.com FM 34-54 COLLECTION CHECKLIST-ELECTRIC POWER POWERPLANTS 1. IDENTIFICATION. Local name and military designation. a. Map reference. Include series and sheet numbers of both tactical and air-ground series. b. Political unit, area, nearest town, UTM coordinates, and geographical coordinates. 2. TYPE. Conventional-steam thermal, nuclear-steam thermal, internal combustion-thermal, hydro-turbine storage, hydro-turbine run-of-river, solar, wind, tidal, and so forth. 3. OWNERSHIP. Government or private. 4. FUNCTION. Public utility, industrial, or both. 5. AREA SERVED. 6. PURPOSE. Base load, peak load, or stand-by. 7. STATISTICS. a.

Total capacity (kW or kVA) and annual production (kWh). b. Generators (numbers, type, and rating of each). 8. CURRENT CHARACTERISTICS. a. Type (direct current; alternating current). b. Generating voltage. c. Phase and hertz. 9. OVERALL CONDITION AND AGE. 10. POWERHOUSE CONSTRUCTION. Material, number of stories, windows, and so forth. 11. TRANSMISSION LINE CONNECTIONS. Number and voltage. 12. FUEL DATA (thermal plants only). a. Type (by grades). b. Quantity used per annum (tons, gallons, cubic feet, pounds, and so forth). c. Sources. Figure I-2. Collection Checklist-Electric Power. I-5