SPECIAL INSTRUCTIONS FOR ELECTRONIC SUBSYSTEMS 5-9 E UROCARGO Euro 4/5 Spare part collection number of the male holder coupling: 98435337. Spare part collection number of the female holder coupling: 98435341 4-pin PTO 1 connectors, optional: ST60 Table 5.6 - 4-pin connector ST60 pin out 4-pin PTO 2 connectors, optional: ST61 Spare part collection number of the male holder coupling: 98435337. Spare part collection number of the female holder coupling: 98435341. Table 5.7 - 4-pin connector ST61 pin out 4-pin PTO 3 connectors, optional: ST62 Spare part collection number of the male holder coupling: 98435337. Spare part collection number of the female holder coupling: 98435341.
Table 5.8 - 4-pin connector ST62 pin out Bodybuilder connectors Print 603.93.431 Base - January 2008 Connections Pin Description Type Cable code Max. load Remarks 1 Counter-reaction PTO INPUT 6131 10 mA PTO engaged indicator signal Closed to ground = PTO engaged Circuit open = PTO not engaged 2 PTO control OUTPUT 9131 1.5 A Electrical cut-in for PTO +24 V. Power output for valve solenoid 3 PTO enable INPUT 0391 10 mA PTO enabling signal Closed to ground = PTO enabled Circuit open = PTO not enabled 4 Ground POWER 0000 1.5 A Ground Connections Pin Description Type Cable code Max.
load Remarks 1 Counter-reaction PTO INPUT 6132 10 mA PTO engaged indicator signal Closed to ground = PTO engaged Circuit open = PTO not engaged 2 PTO control OUTPUT 9132 1.5 A Electrical cut-in for PTO +24 V. Power output for valve solenoid 3 PTO enable INPUT 0392 10 mA PTO enabling signal Closed to ground = PTO enabled Circuit open = PTO not enabled 4 Ground POWER 0000 1.5 A Ground Connections Pin Description Type Cable code Max. load Remar ks 1 Counter-reaction PTO INPUT 6133 10 mA PTO engaged indicator signal Closed to ground = PTO engaged Circuit open = PTO not engaged 2 PTO control OUTPUT 9133 1.5 A Electrical cut-in for PTO +24 V.
Power output for valve solenoid 3 PTO enable INPUT 0393 10 mA PTO enabling signal Closed to ground = PTO enabled Circuit open = PTO not enabled 4 Ground POWER 0000 1.5 A Ground