ISPSoft User Manual 22.1.3 Using G-Code Editor There are 2 options under the G-Code Editor, select G-Code to save the codes in the PLC and G-Code (External SD Card) to save the codes to the external SD Card on the PLC. (Currently, the ISPSoft does not support this function in DVPxxMC). Select one, right-click the selected option and then click New to open the New G-Code Program setting window. Type a name and an item ID for this G-Code. Users can also set up a password to protect the G-Code data. When a password is set, the system will ask for the password upon next editing. Up to 64 sets of G-Code can be created (max. 250KB for each set) in the PLC.
22-4 G code Function Format G3 Anticlockwise circular arc/ helical interpolation N G3 X Y Z I J F _ _ _ __ _ _ N G3 X Y Z I K F _ _ _ __ _ _ N G3 X Y Z J K F _ _ _ _ _ _ _ N G3 X Y Z R F _ _ _ _ _ _ G17 XY plane for circular interpolation N G17 _ G18 XZ plane for circular interpolation N G18 _ G19 YZ plane for circular interpolation N G19 _ G90 Absolute mode N G90 _ G91 Relative mode N G91 _