ISPSoft User Manual Notice for table input: 1. The target speed cannot be set to 0. The objective position also cannot be set to 0 in the relative mode. 2. I number can be used more than once. Users must determine through which row number the I number can be completely outputted. 3. The instruction which the start table outputs is API2718 TPO. API2719 TPWS can be used to modify the output parameters while PLC is running. 23.1.6 Control Mode – Single axis multi-segment Description regarding single axis multi-segment mode setting. No. : The number is generated by the system and the maximum No. is 200. Control Mode: A motion type. Choose Single-axis multi-segment motion . Axis No.:
An axis controlled by the data. ABS/REL mode: Relative Mode increases or decreases based on the current coordinates. Absolute Mode increases or decreases based on the absolute coordinates as target position. Relative mode (Symbol/Address) increases or decreases based on the current coordinate address, symbol or address are allowed. Absolute mode (Symbol/Address) increases or decreases based on the absolute coordinates as target position, symbol or address are allowed. Target position: Target coordinate. For ABS/REL mode , the options include symbol/address. Target speed : Maximum speed of the target. ACC/DEC time: The time to reach target speed and stop. Abort signal (I/M):
When execution of the table is not yet complete and the register of abort signal is set ON, the next segment of position planning is executed. Users can input I for abort number or M for register bane. For information on supported abort numbers, please refer to related product programming manuals. 23-10