omron — Single/Three-Phase 200 V Class Drive

A.2 Single/Three-Phase 200 V Class Drive A.2 Single/Three-Phase 200 V Class Drive Table A.2 Power Ratings Drives with a single-phase power supply input output three-phase power, and cannot run a single-phase motor. The motor capacity (kW) refers to a Yaskawa 4-pole motor. The rated output current of the drive output amps should be equal to or greater than the motor rated current. Input current rating varies depending on the power supply transformer, input reactor, wiring connections, and power supply impedance. Rated motor capacity is calculated with a rated output voltage of 220 V. Carrier frequency is set to Swing PWM. Current derating is required in order to raise the carrier frequency.

Carrier frequency is set to 10 kHz. Current derating is required in order to raise the carrier frequency. Carrier frequency is set to 8 kHz. Current derating is required in order to raise the carrier frequency. Note: Differences between Heavy Duty (HD) ratings and Normal Duty (ND) ratings for the drive include rated input and output current, overload capacity, carrier frequency and current limit. Set parameter C6-01 to “0” (default) for HD or “1” for ND. Specifications A SIEP C710606 33A OYMC AC Drive – J1000 User Manual 163 Item Specification Three-Phase: JZA 20P1 20P2 20P4 20P7 21P5 22P2 24P0 Single-Phase:

JZA B0P1 B0P2 B0P4 B0P7 B1P5 - - Maximum Motor Size Allowed (kW) HD Rating 0.1 0.2 0.4 0.75 1.5 2.2 4.0 ND Rating 0.2 0.4 0.75 1.1 2.2 3.0 5.5 Input Input Current (A) Three-Phase HD Rating 0.7 1.5 2.9 5.8 7.5 11.0 18.9 ND Rating 1.1 1.9 3.9 7.3 10.8 13.9 24.0 Single-Phase HD Rating 1.4 2.8 5.5 11.0 14.1 - - ND Rating 2.0 3.6 7.3 13.8 20.2 - - Output Rated Output Capacity (kVA) HD Rating 0.3 0.6 1.1 1.9 3.0 4.2 6.7 ND Rating 0.5 0.7 1.3 2.3 3.7 4.6 7.5 Output Current (A) HD Rating 0.8 1.6 3.0 5.0 8.0 11.0 17.5 ND Rating 1.2 1.9 3.5(3.3) 6.0 9.6 12.0 19.6 Overload Tolerance ND Rating: 120% of rated output current for 1 minute HD Rating:

150% of rated output current for 1 minute (Derating may be required for applications that start and stop frequently) Carrier Frequency 2 kHz (user-set, 2 to 15 kHz) Max Output Voltage (V) Three-phase 200 to 240 V (proportional to input voltage) Max Output Frequency (Hz) 400 Hz (user-adjustable) Power Supply Rated Voltage Rated Frequency Three-phase power: Three-phase 200 to 240 V 50/60 Hz Single-phase power: 200 to 240 V 50/60 Hz Allowable Voltage Fluctuation -15 to 10% Allowable Frequency Fluctuation ±5% Harmonic Corrective Actions DC Reactor Optional