omron — Defaults by Drive Capacity (o2-04) and ND/HD (C6-01)

B.3 Defaults by Drive Capacity (o2-04) and ND/HD (C6-01) Table B.3 Three-Phase 400 V Class Drives Default Settings by Drive Capacity and ND/HD Setting 184 SIEP C710606 33A OYMC AC Drive – J1000 User Manual No.

Description Unit Default Settings − Model JZA − 40P2 40P4 40P7 41P5 C6-01 Normal/Heavy Duty − HD ND HD ND HD ND HD ND o2-04 Drive Model Selection Hex 91 92 93 94 − Motor rated power kW 0.2 0.4 0.4 0.75 0.75 1.5 1.5 2.2 C6-02 Carrier frequency − 3 7 3 7 3 7 3 7 E2-01 Motor rated current A 0.60 1.00 1.00 1.60 1.60 3.10 3.10 4.20 E2-02 Motor rated slip Hz 2.50 2.90 2.90 2.60 2.60 2.50 2.50 3.00 E2-03 Motor no-load current A 0.40 0.60 0.60 0.80 0.80 1.40 1.40 1.50 E2-05 Motor line-to-line resistance Ω 83.94 38.198 38.198 22.459 22.459 10.1 10.1 6.495 − Momentary power loss ride- through time s 0.1 0.1 0.1 0.1 0.2 0.2 0.3 0.3 − Momentary power loss Baseblock time s 0.2 0.2 0.2 0.3 0.3 0.4 0.4 0.5 No.

Description Unit Default Setting − Model JZA − 42P2 43P0 44P0 C6-01 Normal/Heavy Duty − HD ND HD ND HD ND o2-04 Drive Model Selection − 95 96 97 − Motor rated power kW 2.2 3.0 3.0 3.7 4.0 5.5 C6-02 Carrier frequency − 3 7 3 7 3 7 E2-01 Motor rated current A 4.20 5.70 5.70 7.00 7.00 9.80 E2-02 Motor rated slip Hz 3.00 2.70 2.70 2.70 2.70 1.50 E2-03 Motor no-load current A 1.50 1.90 1.90 2.30 2.30 2.60 E2-05 Motor line-to-line resistance Ω 6.495 4.360 4.360 3.333 3.333 1.595 − Momentary power loss ride-through time s 0.5 0.5 0.5 0.5 0.5 0.5 − Momentary power loss Baseblock time s 0.5 0.5 0.5 0.6 0.6 0.7