omron — Exterior and Mounting Dimensions

2.2 Mechanical Installation u Installation Orientation and Spacing Install the drive upright as illustrated in Figure 2.1 to maintain proper cooling. A B B A – Correct B – Incorrect Figure 2.1 Correct Installation Orientation n Single Drive Installation Figure 2.2 explains the required installation spacing to maintain sufficient space for airflow and wiring. Install the heatsink against a closed surface to avoid diverting cooling air around the heatsink.

Side Clearance Top/Bottom Clearance A A C B C A – 30 mm minimum B – Airflow direction C – 100 mm minimum Figure 2.2 Correct Installation Spacing Mechanical Installation n Multiple Drive Installation When installing multiple drives into the same enclosure panel, mount the drives according to Figure 2.2 . When mounting drives with a minimum side-by-side clearance of 2 mm according to Figure 2.3 , derating must be considered and parameter L8-35 must be set. Refer to Parameter List on page 169 . A 2 D A – Line up the tops of the drives. B – 30 mm minimum C – 100 mm minimum D – Airflow direction Figure 2.3 Space Between Drives (Side-by-Side Mounting) Note:

When installing drives of different heights in the same enclosure panel, the tops of the drives should line up. Leave space between the top and bottom of stacked drives for cooling fan replacement if required. Using this method, it is possible to replace the cooling fans later. u Exterior and Mounting Dimensions Refer to NEMA Type 1 Kit on page 156 for exterior and mounting dimensions for NEMA Type 1. SIEP C710606 33A OYMC AC Drive – J1000 User Manual 27 B B 2 mm C C