5.5 E: Motor Parameters Note: The setting range becomes 0.00 to 130.00 when using JZAB0P2, JZA20P2, JZA40P2 and smaller. Contact the motor manufacturer to find out the line-to-line resistance or measure it manually. When using the manufacturer Motor Test Report, calculate E2-05 by the formulas below. • E-type insulation: Multiply 0.92 times the resistance value (Ω) listed on the Test Report at 75 °C • B-type insulation: Multiply 0.92 times the resistance value (Ω) listed on the Test Report at 75 °C. • F-type insulation: Multiply 0.87 times the resistance value (Ω) listed on the Test Report at 115 °C. Parameter Details 5 SIEP C710606 33A OYMC AC Drive – J1000 User Manual 89 No.
Parameter Name Setting Range Default E2-05 Motor Line-to-Line Resistance 0.000 to 65.000 Ω Depending on o2-04