L-6534VW Operation Guide Basic Operations Adjusting the Print Position for Reverse Feeding When you reverse-feed the substrate using the eye mark for reverse feeding, you can adjust the print position in one of the following three methods. Enter the adjustment value into Reverse Feeding Position Adjustment for the preset for reverse feeding. Adjusting Using Print Data with Ruled Lines Prepare the following in advance. ❏ Print data with ruled lines for aligning ❏ Loupe with scale ❏ Print data for printing Create print data with ruled lines for aligning with the following specifications.
144 Contents Explanation Reference Using print data with ruled lines Print data with ruled lines for alignment, and calculate the adjustment value. This method is highly accurate for alignment and useful when the sensor is located away from the die cutting position of the post-processing device. U “Adjusting Using Print Data with Ruled Lines” on page 144 Measuring with a ruler Print the print data and calculate the adjustment value based on the distance between the eye marks. The accuracy of alignment is lower than the aligning method using print data with ruled lines. This is useful when the sensor is located at the die cutting position of the post-processing device.
U “Adjusting the Print Position Using a Ruler” on page 149 Enter adjusted value If any adjusted value is present and the following conditions are the same, you can reuse the adjustment value. ❏ The same substrate model number for the same manufacturer ❏ Substrate width ❏ Distance from the right edge of the print data to the right edge of the eye mark - Item Explanation Width of ruled lines 1 pixel (0.125 pt) Length of ruled lines 3 mm or more