4. Motion Control Instructions 4.5.11. DMC_CamSwitch The instruction is applied to indicate the execution stage of the electronic cam operation. The corresponding output of the instruction remains high for one full cycle when the electronic cam operation reaches or exceeds one preset stage. Explanation of the Instruction: Explanation of input and output parameter of the instruction: DVP-MC operating manual 4-103 API Indicate cam operation stage Applicable Model 69 DMC CamSwitch _ 10MC11T Available Parameter name Explanation Data type device This instruction is executed when “Enable” M,I,Q, Enable BOOL changes from OFF to ON.
constant CamTableID Specify the electronic cam table number UINT Constant, D Specify the execution stage of electronic cam Percent 1 operation within one cam cycle. Range: REAL Constant, D 0~99.9999 (Unit: %) Specify the execution stage of electronic cam Percent 2 operation within one cam cycle. Range: REAL Constant, D 0~99.9999 (Unit: %) Specify the execution stage of electronic cam Percent 3 operation within one cam cycle. Range: REAL Constant, D 0~99.9999 (Unit: %) Specify the execution stage of electronic cam Percent 4 operation within one cam cycle. Range: REAL Constant, D 0~99.9999 (Unit: %) Specify the execution stage of electronic cam Percent 5 operation within one cam cycle. Range:
REAL Constant, D 0~99.9999 (Unit: %) Specify the execution stage of electronic cam Percent 6 operation within one cam cycle. Range: REAL Constant, D 0~99.9999 (Unit: %) Specify the execution stage of electronic cam Percent 7 operation within one cam cycle. Range: REAL Constant, D 0~99.9999 (Unit: %) Specify the execution stage of electronic cam Percent 8 operation within one cam cycle. Range: REAL Constant, D 0~99.9999 (Unit: %)