4. Motion Control Instruction 4.6.37. MOV_WB Explanation of the instruction: MOV_WB is used for sending multiple word device values to the bit devices. When EN is on, the register value with S1 as the starting one is sent to the bit device with D as the starting one. The sent word device data length is specified by S2. When the data length S2 is larger than maximum 64, it is counted as 64. And the part above 64 is invalid. Explanation of input and output parameter of the instruction: Note: If the register of the instruction exceeds the range of register of the controller, only the data in the register within the valid range can be sent.

 Program example 4-140 DVP-MC operating manual API Move multiple register values to multiple bit devices Controller MOV WB 164 _ 10MC11T Parameter Data Available Explanation name type device EN “MOV WB” is executed as “EN” turns on. _ BOOL M,I,Q, constant S1 Storage area for data source INT D S2 The length of the register of the transmitted zone, the max value for S2 is 64. UINT Constant,D D The starting one of the target bit device. BOOL M,Q