9. STARTING MOTOR (2) Disassembly procedure 1) Nut M8 Remove the magnetic switch nut M8 (12 mm), and disconnect the connecting wire. 2) Screw M4 (2) 3) Through bolt M5 (2) 4) Rear cover Remove the M4 screw fastening the brush holder and remove through bolt M5 for rear cover removal. 5) Brush holder Pull the brush spring up with the brush spring puller. On the negative (–) side, bring the brush spring into contact with the side of the brush for lifting from the commutator sur- face. On the positive (+) side, extract the brush from the brush holder. 9-6 82E-5 – 98E-5 SERIES