Delta — Group 4 Input Function Parameters

Chapter 4 Parameters | Group 4 Input Function Parameters 4-10 Revision 2016/03, 6ELE, V1.14 Parameter Function Setting Factory Setting Custome r 04.00 Keypad Potentiometer Bias 0.0 to 100.0 % 0.0 04.01 Keypad Potentiometer Bias Polarity 0: Positive bias 1: Negative bias 00 04.02 Keypad Potentiometer Gain 0.1 to 200.0 % 100.0 04.03 Keypad Potentiometer Negative Bias, Reverse Motion Enable/Disable 0: No negative bias command 1: Negative bias: REV motion enabled 0 04.04 2-wire/3-wire Operation Control Modes 0: 2-wire: FWD/STOP, REV/STOP 1: 2-wire: FWD/REV, RUN/STOP 2: 3-wire operation 0 04.05 Multi-function Input Terminal (MI3) 0: No function 1: Multi-Step speed command 1 2:

Multi-Step speed command 2 3: Multi-Step speed command 3 4: Multi-Step speed command 4 5: External reset 6: Accel/Decel inhibit 7: Accel/Decel time selection command 8: Jog Operation 9: External base block 10: Up: Increment master frequency 11: Down: Decrement master frequency 12: Counter Trigger Signal 13: Counter reset 14: E.F. External Fault Input 15: PID function disabled 16: Output shutoff stop 17: Parameter lock enable 18: Operation command selection (external terminals) 19: Operation command selection(keypad) 20: Operation command selection(communication) 21: FWD/REV command 22:

Source of second frequency command 23 Simple position stop by forward limit 24 Simple position stop by reverse limit 25 Multi-pumps switch by Hand / Auto mode. 1 04.06 Multi-function Input Terminal (MI4) 2 04.07 Multi-function Input Terminal (MI5) 3 04.08 Multi-function Input Terminal (MI6) 4