Mitsubishi FR-A800 — 2.9 Parameter settings for a motor with encoder

Parameter settings for the motor under Vector control *1 Offline auto tuning is required. (Refer to page 550 .) *2 Set this parameter according to the motor. *3 Use the thermal protector input provided with the motor. When using the inverter with the SF-V5RU (1500 r/min series), refer to the following table to set Pr.83 Rated motor voltage and Pr.84 Rated motor frequency . When using the inverter with the SF-V5RU1, SF-V5RU3, or SF-V5RU4, refer to the following table to set Pr.83 Rated motor voltage and Pr.84 Rated motor frequency. 96 2.

INSTALLATION AND WIRING 2.9 Parameter settings for a motor with encoder Motor model Pr.9 Electronic thermal O/L relay Pr.71 Applied motor Pr.80 Motor capacity Pr.81 Number of motor poles Pr.359/Pr.852 Encoder rotation direction Pr.369/Pr.851 Number of encoder pulses Mitsubishi Electric standard motor SF-JR Rated motor current 0 (initial value) Motor capacity Number of motor poles 1 (initial value) 1024 (initial value) SF-JR 4P 1.5 kW or lower Rated motor current 20 Motor capacity 4 1 (initial value) 1024 (initial value) SF-HR Rated motor current 40 Motor capacity Number of motor poles 1 (initial value) 1024 (initial value) Others Rated motor current 0 (3)*1 Motor capacity Number of motor poles *2 *2 Mitsubishi Electric constant-torque motor SF-JRCA 4P Rated motor current 1 Motor capacity 4 1 (initial value) 1024 (initial value) SF-HRCA Rated motor current 50 Motor capacity Number of motor poles 1 (initial value) 1024 (initial value) Others Rated motor current 1 (13)*1 Motor capacity Number of motor poles *2 *2 Vector control dedicated motor SF-V5RU (1500 r/min series) 0*3 30 Motor capacity 4 1 (initial value) 2048 SF-V5RU (other than the 1500 r/min series) 0*3 1 (13)*1 Motor capacity 4 1 (initial value) 2048 SF-THY 0*3 30 (33)*1 Motor capacity 4 1 (initial value) 2048 Other manufacturer's standard motor — Rated motor current 0 (3)*1 Motor capacity Number of motor poles *2 *2 Other manufacturer's constant-torque motor — Rated motor current 1 (13)*1 Motor capacity Number of motor poles *2 *2 PM motor Refer to the Instruction Manual of the FR-A8APR.

Motor capacity SF-V5RU Motor capacity SF-V5RU 200 V 400 V 200 V 400 V Pr.83 (V) Pr.84 (Hz) Pr.83 (V) Pr.84 (Hz) Pr.83 (V) Pr.84 (Hz) Pr.83 (V) Pr.84 (Hz) 1.5 kW 188 52 345 52 18.5 kW 171 51 346 51 2.2 kW 188 52 360 52 22 kW 160 51 336 51 3.7 kW 190 52 363 52 30 kW 178 51 328 51 5.5 kW 165 51 322 51 37 kW 166 51 332 51 7.5 kW 164 51 331 51 45 kW 171 51 342 51 11 kW 171 51 320 51 55 kW 159 51 317 51 15 kW 164 51 330 51 Motor model Pr.83 setting Pr.84 setting 200 V class 400 V class SF-V5RU1-30kW or lower 160 V 320 V 33.33 Hz SF-V5RU1-37kW 170 V 340 V SF-V5RU3-22kW or lower 160 V 320 V SF-V5RU3, 30kW 170 V 340 V SF-V5RU4-3.7kW and 7.5kW 150 V 300 V 16.67 Hz SF-V5RU4 and motors other than described above 160 V 320 V