EPSON — Main electric panel

Name and Function of Each Part Control Panel Main electric panel 22 No. Name Description 1 Power lamp Displays the printer's operational status. On: The power is on. Off:The power is off. 2 Emergency stop button Stops operation of this machine immediately. 3 Main power switch Turns the power on and off. 0: Turns the power off. 1: Turns the power on. 4 Reset button Press this button after selecting Setpoint to start the Set- point operation. 5 Maintenance key switch Insert the maintenance key when reapplying the glue. For more information, refer to "Glue Re-Application" in the Maintenance Guide.

CAUTION If the power is turned on while the maintenance key is still inserted in the maintenance key switch, the belt operation safety function during printing (device operation) will be disabled, resulting in a dangerous situation. Therefore, do not insert the maintenance key except for when applying glue. The maintenance key should be managed by someone who has been authorized by the person in charge at the company. Do not leave it inserted in the maintenance key switch of the main electric panel. The person in charge is responsible for storing the maintenance key in a safe, locked location.