WIRING AND CUSTOM APPLICATION SUGGESTIONS Using your DCI1 for a variety of applications is very simple. You just need to keep in mind the ratings for the relay contacts listed on the specification page to avoid any problems and use a common sense approach for personal safety. If you need to operate a simple low voltage DC circuit or switch on and off a low wattage 120 VAC lighting application, interface the your wiring di- rectly to the J1 through J4 screw terminals and your off to the races!
For heav- ily inductive loads such as a large motor or applications that exceed the power ratings of the relays, the following diagrams will help you get started wiring the DCI1 as a trigger source for a larger relay or similar device. Typical Low Power DC Wiring: -LED switch application Line Level Audio Input Wiring: J6 Front View -Custom Audio feed wiring arrangement using a standard RJ-11 Patch cable. Audio GND + Audio In DCI1 22