RIEVTECH STUDIO SOFTWARE MANUAL Note: You need to use the character input component to enter the password to SRW100 ~ 103. l Return to original screen when Screensavers is over If you check the option “ Return to original screen when Screensavers is over ” , it will return to the original screen when you click the HMI screen. Of course, if you set a password, the system message window will pop up to prompt you to enter the password before return to the original screen. Note: If you don ’ t check the option “ Return to original screen when Screensavers is over ” , it will still stay in the screensaver window when the screensaver is over.
4.10.2.1.3 Local Register EndianOrder The “ Local Register Endian Order ” refers to the order of the high byte and the low byte. For example, a 32-bit register LW0=0x12345678. If you select the “ 4321 ” mode, then the word register LW0=0x1234 and the word register LW1=0x5678. If you select the “ 2143 ” mode, then the word register LW0=0x5678 and the word register LW1=0x1234. 4.10.2.1.4 Scrollbar For some components without setting the scrollbar width, you can set it in the “ Scrollbar Width ” option. For example, you set the scrollbar width for the pop up window component here.
4.10.2.1.5 Initialization l InitialWindow The “ Initial Window ” refers to the first displayed configuration window after the project is downloaded to the HMI or the HMI is powered on. l Initial Macro After check the “ Initial Macro ” , you can specify a Macro to run before the configuration window is displayed. This function can realize the initial work of your project. 4.10.2.1.6 Main Window(HOME) 385