ROLAND — 17/21. Test Mode

E-600 July, 1999 While you are in test mode (except in Device Check mode), you can adjust the LCD contrast by rotating the Rotary Encoder keeping the Part Balance [Keyboard] button pressed. NOTE: Do not play the keyboard while you are in test mode. If there is a malfunction, press the Part Balance [Accomp]button several times until the display "Product Information" will be shown. Then start the test again. When the writing [Next] is displayed at the bottom of the screen, you can go on by touching it ([Next]). While you are in test mode, you can go to the following test by pressing the Part Balance [Accomp] button. How to go to the following test.

While pressing both [Track 4] and [Play] buttons, press Part Balance [Accomp]. The following display will appear and you will enter test mode. To enter the Test Mode Test Main Menu' In order to enter the different tests listed below, press each time the button "Next " or the button " Part Volume Accomp ". Required items: · MIDI Cable …… 1 (1.5 m) · Microphone · Oscilloscope · KR-575 LCD Calibration sheet (part number 01675978) · Touch-pen for PMA-5 (part number 00900545) · 3,5inch Floppy Disk (formatted by E-600/ 2 HD x 1,2; DD x 1) TEST MODE 1. Calibration of the Touch Panel 2. Display of the Device Check and Rom Version 3. Factory Preset Setting 4. Control of buttons and LEDs 5.

Control of the Speaker Panning and of Effect Sound 6. Esp check 7. A/D check 8. Touch Panel A/D check 9. Encoder check 10.MIDI check 11.Microphone check 12.FDD check 13.LCD check 14.LCD contrast check 15.Setup and Destination 16.Audio check This way, the writing "Touch Me" will appear to show the correct order, so please follow this indication. During the Calibration, do not touch any point except "Touch Me". After touching the four points, the calibration step ends and the display will show : After positioning the sheet, the display will appear as follows: Touch the lower corner of each slit on the sheet with the Touch pen according to the numbering shown in the following picture).

When the E-600 recognizes the touch, "+" will change into "O". Place the Calibration sheet on the Touch Panel as shown in the following picture. The side with a notch should become the upper. To perform this test, original pen (Touch Pen for PMA-5, P/no. 00900545) and jig (KR-575Calibration Sheet, P/No. 01675978) are required. Please order these jigs from the local Roland Service Center if necessary. Calibrate the position of the Touch Panel this way. 1. Calibration of the Touch Panel 1 4 + + + + T ouch Me. 3 2 17