S UPER S ERVER 8060 Manual Installing the Chassis Rails: Position the fixed chassis rail sections you just removed along the side of the 8060 chassis making sure the five screw holes line up. Be aware that these two rails are left/right specific. Screw the rail securely to the side of the chassis (see Figure 2-2). Repeat this procedure for the other rail on the other side of the chassis. which serves two functions. The first is to lock the server into place Locking Tabs: As you have seen, both chassis rails have a locking tab, when installed and pushed fully into the rack, which is its normal position. These tabs also lock the server in place when fully extended from the rack.
This prevents the server from coming completely out of the rack when you pull it out for servicing. Locking Tab Figure 2-2. Installing the Chassis Rails Installing the Rack Rails: Determine where you want to place the SuperServer 8060 in the rack. rail/sliding rail guide assemblies at the desired location in the rack, (See Rack and Server Precautions in Section 2-3.) Position the fixed rack keeping the sliding rail guide facing the inside of the rack. Screw the assembly securely to the rack using the brackets provided. Attach the other assembly to the other side of the rack, making both are at the exact same height and with the rail guides facing inward (see Figure 2-3). 2-4