3-7 Parameter List 3 Operation * 2nd control is displayed when SET (08) is allocated to one of from C001 to C005. 3-26 Parameter No. Function name Monitor or data range (Digital Operator) Default setting Changes during operation Unit Page RUN mode, Acceleration/Deceleration functions A085 RUN mode selection 00: Normal operation 01: Energy-saving operation 00 No - 4-23 A086 Energy-saving response/ accuracy adjustment 0 to 100 50 No % 4-23 A092 Acceleration time 2 0.01 to 99.99 100.0 to 999.9 1000. to 3000. 15.00 Yes s 4-24 A292 *2nd acceleration time 2 15.00 A093 Deceleration time 2 0.01 to 99.99 100.0 to 999.9 1000. to 3000.
15.00 Yes s 4-24 A293 *2nd deceleration time 2 15.00 A094 2-step acceleration/ deceleration selection 00: Switched via multi-function input 09 (2CH) 01: Switched by setting 00 No ⎯ 4-24 A294 *2nd 2-step acceleration/ deceleration selection 00 A095 2-step acceleration frequency 0.0 to 400.0 0.0 No Hz 4-24 A295 *2nd 2-step acceleration frequency 0.0 A096 2-step deceleration frequency 0.0 to 400.0 0.0 No Hz 4-24 A296 *2nd 2-step deceleration frequency 0.0 A097 Acceleration pattern selection 00: Line 01: S-shape curve 00 No ⎯ 4-25 A098 Deceleration pattern selection 00: Line 01: S-shape curve 00 No ⎯ 4-25