Appendix Internal parameter settings Internal parameter settings can be changed with the following: ENPC protocol: Epson provides a dedicated utility that makes miscellaneous setting with the ENPC protocol. HTTP browser: An HTTP browser can make setting when connected to the module. arp commands and ping commands (Only IP address is settable.): This function is available only when it has been enabled. The setting can be made only from a host PC that supports both arp and ping commands and is in the same segment as the module.
67 Article Parameters Default values Utility Browser Status sheet print View Setting View Setting IP address 192.168.192.168 Yes Yes Yes Yes Yes Subnet mask 255.255.255.0 Yes Yes Yes Yes Yes Gateway address 0.0.0.0 Yes Yes Yes Yes Yes DHCP Enable/Disable Disable Yes Yes Yes Yes Yes APIPA Enable/Disable Disable Yes Yes Yes Yes Yes Arp/ping IP setting Enable/Disable Enable Yes Yes Yes Yes No Community name 1 (read-only) Max. 16 characters “public” Yes No Yes No Yes Community name 2 (read-write) Max. 16 characters None Yes Yes Yes Yes Yes IP Trap 1 Enable Enable/Disable Disable Yes Yes Yes Yes No IP Trap 2 Enable Enable/Disable Disable Yes Yes Yes Yes No Community name (IP Trap #1) Max.
16 characters None Yes Yes Yes Yes No Community name (IP Trap #2) Max. 16 characters None Yes Yes Yes Yes No IP trap #1 address None Yes Yes Yes Yes No IP trap #2 address None Yes Yes Yes Yes No Password None No Yes No Yes No Physical layer setting Auto negotiation /10Base-T Half /10Base-T Full /100Base-TX Half /100Base-TX Full Auto negotiation Yes Yes Yes Yes Yes Hardware version — — Yes No Yes No Yes Firmware version — — Yes No Yes No Yes MAC address — — Yes No Yes No Yes