beckhoff TS4100 — 5.5.9 FB_CTRL_PT2

PLC-API TYPE ST_CTRL_PT1_PARAMS : STRUCT tCtrlCycleTime : TIME := T#0ms; (* controller cycle time [TIME] *) tTaskCycleTime : TIME := T#0ms; (* task cycle time [TIME] *) fKp : FLOAT := 0; (* proportional gain *) tT1 : TIME := T#0ms; (* T1 *) END_STRUCT END_TYPE tCtrlCycleTime : Cycle time with which the control loop is processed. This must be greater than or equal to the TaskCycleTime. The function block uses this input value to calculate internally whether the state and the output values have to be updated in the current cycle. tTaskCycleTime : Cycle time with which the function block is called.

If the function block is called in every cycle this corresponds to the task cycle time of the calling task. fKp : Controller amplification / transfer coefficient tT1 : Time constant Requirements 5.5.9 FB_CTRL_PT2 The function block provides a non-oscillating PT2 transfer element in the functional diagram. Transfer function: TS4100 92 Version: 1.1 Development Environment Target System PLC libraries to include TwinCAT v2.8 PC (i386) TcControllerToolbox.lib TwinCAT v2.9 from Build 947 BC [} 10] TcControllerToolbox.lb6 TwinCAT v2.9 from Build 956 BX [} 10] TcControllerToolbox.lbx