sinee — 6.2Table of functional parameters

User Manual of EM730 Series Inverter 112 F12.02 Parameter locking 0: do not lock 1: reference input not locked 2: all locked, except for this function code 0 ● 0x0C02 F12.03 Parameter copying 0: no operation 1: parameter upload to keyboard 2: download parameters to inverter(F01 and F14 groups do not download) 3: download parameters to inverter 0 〇 0x0C03 F12.09 Load speed display coefficient 0.01~600.00 30.00 ● 0x0C09 F12.10 UP/DOWN acceleration and deceleration rate 0.00: automatic rate 0.05~500.00Hz/s 5.00H z/s 〇 0x0C0A F12.11 Options of UP/DOWN offset clearing 0: not clear (clear changes in main frequency setting) 1: clear in non-running state 2: clear by releasing the UP/DOWN button 3:

clear once in non-running state 0 〇 0x0C0B F12.12 Options of UP/DOWN power-down saving of offset 0: do not save 1: save (valid after the offset is modified) 1 〇 0x0C0C F12.13 Power meter resetting 0: do not clear 1: clear 0 ● 0x0C0D F12.14 Restoration of factory defaults 0: no operation 1: restoration of factory defaults (excluding the motor parameters, inverter parameters, manufacturer parameters, running and power-on time record) 0 〇 0x0C0E F12.15 Cumulative power-on time (h) 0~65535 h XXX × 0x0C0F F12.16 Cumulative power-on time (min) 0 ~ 59 min XXX × 0x0C10 F12.17 Cumulative running time (h) 0 ~ 65535 h XXX × 0x0C11 F12.18 Cumulative running time (min) 0 ~ 59 min XXX × 0x0C12