sinee — 7.3Function Parameter Group of Input Terminal of F02

User Manual of EM730 Series Inverter invalid in the open status; When the bit is set to 1, the multi-function input terminal is valid in the open status and invalid in the closed status. These function code are subject to bit operation. You only need to set the corresponding bit to 0 or 1. Take F02.15 as an example, as shown in the following table: Table 7- 7 Function Code Details of Bit Operation The seventh bit is reserved and cannot be set. The specific displayed value does not mean anything. For example: To set the terminal X1 to reverse logic, you only need to set the 0 th bit corresponding to X1 to 1, i.e. F02.15=xxx xxxx1.

To set the terminals X1 and X5 to reverse logic, you only need to set the 0 th bit corresponding to X1 and 4 th bit corresponding to X5 to 1. That is, 02.15=xxx 1xxx1. ★ This function is for logic matching with other external devices. Fig. 7- 13 Schematic Diagram of Terminal Filter Sampling Since the multi-function input terminal is triggered by level or pulse, digital filtering is 180 Setting item * * * X5 X4 X3 X2 X1 Corresponding bit * * * 4 3 2 1 0 Settings * * * 0/1 0/1 0/1 0/1 0/1 Function code Function code name Parameter description Unit Default setting Attribute mailing address F02.17 Filtering times of digital input terminal 0~100; 0: no filtering; n:

sampling once in n ms 2 〇 0x0211