User Manual of EM760 High-Performance Inverter When the simple PLC is running, all of the segments 1 - 15 can have the operating frequency, operating direction, acceleration/deceleration time and operating time in the entire segment set separately. This is described below with the 13 th segment (the last segment) as an example. The specific operation is shown in Fig. 6-10. F08.12=50.00 : the operating frequency of 13 th segment is 50.00Hz. F08.43=31 : the operating direction in the 13 th segment is reverse, and the acceleration and deceleration are controlled based on the acceleration and deceleration time 4 (F15.07/F15.08). 103 F08.43 Setting of the thirteenth segment Ones place:
Running direction options 0: forward 1: reverse Tens place: Acceleration and deceleration time options 0: acceleration and deceleration time 1 1: acceleration and deceleration time 2 2: acceleration and deceleration time 3 3: acceleration and deceleration time 4 0 ● F08.44 Running time of the thirteenth segment 0.0~6000.0 s/min 5.0 ● F08.45 Setting of the fourteenth segment Ones place: Running direction options 0: forward 1: reverse Tens place: Acceleration and deceleration time options 0: acceleration and deceleration time 1 1: acceleration and deceleration time 2 2: acceleration and deceleration time 3 3:
acceleration and deceleration time 4 0 ● F08.46 Running time of the fourteenth segment 0.0~6000.0 s/min 5.0 ● F08.47 Setting of the fifteenth segment Ones place: Running direction options 0: forward 1: reverse Tens place: Acceleration and deceleration time options 0: acceleration and deceleration time 1 1: acceleration and deceleration time 2 2: acceleration and deceleration time 3 3: acceleration and deceleration time 4 0 ● F08.48 Running time of the fifteenth segment 0.0~6000.0 s/min 5.0 ●