User Manual of EM760 High-Performance Inverter The system has four groups (F00.14 and F00.15 in the first group) of acceleration and deceleration time options to meet different needs for normal operation. After completing the setting, the user can switch them via the combination of digital input functions “19: acceleration and deceleration time terminal 1” and “20: acceleration and deceleration time terminal 2”. See “Table 6- 12 Function List of Multi-function Digital Input Terminals” for details.
117 F15.04 Deceleration time 2 0.00~650.00(F15.13=0) 0.0~6500.0(F15.13=1) 0~65000(F15.13=2) s 15.00 ● F15.05 Acceleration time 3 0.00~650.00(F15.13=0) 0.0~6500.0(F15.13=1) 0~65000(F15.13=2) s 15.00 ● F15.06 Deceleration time 3 0.00~650.00(F15.13=0) 0.0~6500.0(F15.13=1) 0~65000(F15.13=2) s 15.00 ● F15.07 Acceleration time 4 0.00~650.00(F15.13=0) 0.0~6500.0(F15.13=1) 0~65000(F15.13=2) s 15.00 ● F15.08 Deceleration time 4 0.00~650.00(F15.13=0) 0.0~6500.0(F15.13=1) 0~65000(F15.13=2) s 15.00 ● F15.09 Fundamental frequency of acceleration and deceleration time 0: maximum frequency F00.16 1: 50.00Hz 2: set frequency 0 〇