sinee — 6.8 Communication setting

User Manual of EM760 High-Performance Inverter 6.8 Communication setting The EM760 series inverter supports the RTU format Modbus protocol, and the “single-master multi-slave” communication network with RS-485 bus. 163 F18.40 VF separation output voltage Display the actual output voltage of VF separation in a real-time manner. Scope:

0.0 to rated voltage ofthe motor V F18.41~ F18.45 Reserved F18.46 Output frequency symbol 0~65535 F18.47~ F18.50 Reserved F18.51 PID output -100.0~100.0 % F18.52~ F18.57 F18.58 Feedback pulse high Higher bit of encoder feedback pulse (hexadecimal) F18.59 Feedback pulse low Lower bit of encoder feedback pulse (hexadecimal) F18.60 Inverter temperature -40~200 ℃ F18.67 Cumulative energy saving MWH 0~65535 MWh F18.68 Cumulative energy saving kWH 0.0~999.9 kWh F18.69 High cumulative cost saving (*1000) 0~65535 F18.70 Low cumulative cost saving 0.0~999.9 F18.71 Power-frequency power consumption MWH 0~65535 MWh F18.72 Power-frequency power consumption kWH 0.0~999.9 kWh