User Manual of EM760 High-Performance Inverter Settings of mapping parameters are as follows: F45.00=1 (mapping effective) F45.01=4608 (source address 1) F45.02=4608 (target address 1) F45.04=4609 (source address 2) F45.05=4614 (target address 2) F45.07=4610 (source address 3) F45.08=4624 (target address 3) F45.10=4611 (source address 4) F45.11=4630 (target address 4) 6.9 Technology 6.9.1 Industry application macro F16.00=0: general model Since the inverter is a general-purpose product, relevant functions for each application should not be enabled. 6.9.1.1 Water supply application F16.00=1:
water supply application The inverter serves as a PID-regulated control product for constant-pressure water supply. 170 Function code of industry application macro Function codename Parameter description Unit Default setting Attribute F16.00 Industry application 0: Universal model 1: Water supply application 2: Reserved 3: Winding application (see 6.9.2) 4: fan application 5: Spindle application ofmachine tool 6: Polisher application 7: High-speed motor application 8: Reserved 9: EM100 communication macro 10: EM303B communication macro 0 O