sinee — Chapter 11 Function Code Table

User Manual of EM760 High-Performance Inverter 318 4: quick stop 5: free stop F12.01 Options of stop function of STOP key 0: valid only in keyboard control 1: with all command channels valid 1 O 0x0C01 F12.02 Parameter locking 0: do not lock 1: reference input not locked 2: all locked, except for this function code 0 ● 0x0C02 F12.03 Parameter copying 0: No operation 1: parameter upload to keyboard 2: Download parameters to inverter (excluding F01 and F14) 3: Download parameters to inverter 0 O 0x0C03 F12.09 Load speed display coefficient 0.01~600.00 30.00 ● 0x0C09 F12.10 UP/DOWN acceleration and deceleration rate 0.00:

automatic rate 0.01~500.00 Hz/s 5.00 O 0x0C0A F12.11 Options of UP/DOWN offset clearing 0: do not clear 1: clear in non-running state 2: clear when UP/DOWN invalid 0 O 0x0C0B F12.12 Options of UP/DOWN power- down saving of offset 0: do not save 1: save (valid after the offset is modified) 1 O 0x0C0C F12.13 Power meter resetting 0: do not clear 1: clear 0 ● 0x0C0D F12.14 Restoration of default setting 0: No operation 1: restoration of factory defaults (excluding the motor parameters, inverter parameters, manufacturer parameters, running and power- on time record) 2:

restoration of factory defaults (including motor and application macro parameter) 0 O 0x0C0E F12.15 Cumulative power- on time (h) 0~65535 h XXX × 0x0C0F