omron — Communication Function

4-2 Function Mode 4 Functions *1. The Inverter's rated current is "1000". *2. The second decimal place is ignored when the value is over 10000 (100.0 seconds). 4-82 Register No. Function name Parameter No. R/W function Data Resolution 0073h AVR voltage selection A082 R/W 200-V class 0: 200 V 1: 215 V 2: 220 V 3: 230 V 4: 240 V  400-V class 0: 380 V 1: 400 V 2: 415 V 3: 440 V 4: 460 V 5:

480 V 0074h Acceleration time 2 A092 (HIGH) R/W 0 to 300000 *2 0.01 [s] 0075h A092 (LOW) R/W 0076h 2nd acceleration time 2 A292 (HIGH) R/W 0 to 300000 *2 0.01 [s] 0077h A292 (LOW) R/W 0078h Deceleration time 2 A093 (HIGH) R/W 0 to 300000 *2 0.01 [s] 0079h A093 (LOW) R/W 007Ah 2nd deceleration time 2 A293 (HIGH) R/W 0 to 300000 *2 0.01 [s] 007Bh A293 (LOW) R/W 007Ch 2-step acceleration/ deceleration selection A094 R/W 0: Switched via terminal 2CH 1: Switched by setting  007Dh 2nd 2-step acceleration/ deceleration selection A294 R/W 0: Switched via terminal 2CH 1:

Switched by setting  007Eh 2-step acceleration frequency A095 R/W 0 to 4000 0.1 [Hz] 007Fh 2nd 2-step acceleration frequency A295 R/W 0 to 4000 0.1 [Hz] 0080h 2-step deceleration frequency A096 R/W 0 to 4000 0.1 [Hz] 0081h 2nd 2-step deceleration frequency A296 R/W 0 to 4000 0.1 [Hz] 0082h Acceleration pattern selection A097 R/W 0: Line 1: S-shape curve  0083h Deceleration pattern selection A098 R/W 0: Line 1: S-shape curve 