omron — ASCII Method

4-4 Communication Function •Response frame Frame format 4 Functions * Error Code List During communication with all stations, the Inverter sends no response. 4-152 STX Station No. NAK Error code BCC CR Description Data size Setting STX Control code (Start of TeXt) 1 byte STX (0x02) Station No. Station No. of the target Inverter 2 bytes 01 to 32 NAK Control code (Negative AcKnowledge) 1 byte NAK (0x15) Error code Communication error status 2 bytes * BCC Block check code 2 bytes Exclusive OR from station No. to data.

(Refer to page 4-153.) CR Control code (Carriage Return) 1 byte CR (0x0D) Error code Description 01H 02H 03H 04H 05H 06H 07H 08H   11H 12H 13H 14H 15H 16H 17H Parity error Checksum error Framing error Overrun error Protocol error ASCII code error Receiving buffer overrun error Receiving timeout error   Command invalid error  Execution disabled error   Parameter invalid error 