No.20S025-02 8.4 Exposure Time This parameter sets variable exposure time. GenICam Parameters (*1) The approximate value of set value, sets to camera and display it. 8.5 Trigger These parameters set operational mode (trigger mode) and trigger type. The selectable trigger types are listed in below table GenICam Parameters STC-MBS510CXP6 / STC-MCS510CXP6 Product Specifications and User’s Guide 26/49 ExposureMode IEnumeration Type Exposure control selection Selection: “Off”, “Timed” and “TriggerWidth” Off: Exposure time is “1 / Frame rate” Timed: Exposure time is “ExposureTime” TriggerWidth: Exposure time is active pulse duration of trigger signal Exposure time (in μsecond) (*1) Range:
1.000000 to 16,777,215.000000 Default: 10,065.0 ExposureTime [ExposureTime Selector] IFloat Type TriggerMode IEnumeration Type Operational mode (trigger mode) selection Off: Free run operation (Default) On: Trigger operation TriggerSource IEnumeration Type Trigger type selection * Please refers below table for details of trigger type TriggerOverlap IEnumeration Type Trigger Overlap function selection Off: Trigger overlap function is disabled (Default) ReadOut:
Trigger overlap function is enabled Software Software trigger signal that generates by TriggerSoftware (Default) Line0 External hardware trigger through Line0 Line1 External hardware trigger through Line1 Line2 External hardware trigger through Line2 Line3 External hardware trigger through Line3 LinkTrigger0 CXP trigger packet trigger