Delta · 20 стр.

TP04P Text Panel + PLC Manual: Delta TP Series Setup & Safety (EN)

Оригинальное название: 5012625001-4P02 TSE

Читать онлайн

Похожие инструкции

Текст документа

………………………………………………………………… ѓ ENGLISH ѓ ………………………………………………………………… Thank you for choosing Delta TP series products. TP04P is composed of a text panel and a PLC. It supports abundant instructions. The capacity of the program memory it supports is 8K steps. TP04P features the same program download port shared by both PLC and TP editing software: WPLSoft/ISPSoft and TPEditor. It also offers various graphical objects for developing the program. The user can also obtain higher efficiency by purchasing additional extension cards, which increase the program portability and save the program download time. Please ensure to use TP series with Delta power supply module, DVPPS01, DVPPS02 or DVPPS05.

EN a TP04P is an OPEN-TYPE device. It should be installed in a control cabinet free of airborne dust, humidity, electric shock and vibration. To prevent non-maintenance staff from operating TP04P, or to prevent an accident from damaging TP04P, the control cabinet in which TP04P is installed should be equipped with a safeguard. For example, the control cabinet in which TP04P is installed can be unlocked with a special tool or key. EN a DO NOT connect AC power to any of I/O terminals, otherwise serious damage may occur. Please check all wiring again before TP04P is powered up. After TP04P is disconnected, Do NOT touch any terminals in a minute.

Make sure that the ground terminal on TP04P is correctly grounded in order to prevent electromagnetic interference. FR a TP04P est un module OUVERT. Il doit ktre installй que dans une enceinte protectrice (boitier, armoire, etc.) saine, dйpourvue de poussiиre, d’humiditй, de vibrations et hors d’atteinte des chocs йlectriques. La protection doit йviter que les personnes non habilitйes а la maintenance puissent accйder а l’appareil (par exemple, une clй ou un outil doivent ktre nйcessaire pour ouvrir a protection). FR a Ne pas appliquer la tension secteur sur les bornes d’entrйes/Sorties, ou l’appareil TP04P pourra ktre endommagй.

Merci de vйrifier encore une fois le cвblage avant la mise sous tension du TP04P. Lors de la dйconnection de l’appareil, ne pas toucher les connecteurs dans la minute suivante. Vйrifier que la terre est bien reliйe au connecteur de terre afin d’йviter toute interfйrence йlectromagnйtique. ѓ Product Outline and Dimensions y Front Panel Power indicator Alarm indicator User-defined key Escape/Exit key Display area Left/Right keys Function/ Nemeric keys Enter key Up/Down keys Figure1 y Back Panel Input/output terminal blocks Input/output terminal blocks Program upload/download communication port (USB) Program copy card interface DC power supply RS485 communication Run/Stop switch Figure2 - 1 -

Стр. 2

y Front View and Right Side View (Units: mm, [ ]: inch) 108.6 [4.276] y Mounting Dimensions (Units: mm, [ ]: inch) y Top View (Units: mm, [ ]: inch) 95.5~97.0 [ ] 3.7598~3.8188 [2.016] Figure4 162.7~164.0 [6.4055~6.4567] Thickness Range 0.5~5mm ѓ Function Specifications - 2 - 175.8 [6.921] 59.2 91.73 [3.613] Figure3 51.2 6] Figure5 Model TP04P series Spec. PLC program capacity 8k steps Screen type/Display STN-LCD/Monochromatic color Driver Delta automation products Function/Numeric keys 0~9, ESC, F, Enter and Up/Down/Left/Right keys Alarm LED indicator Power indication (Blinking for three times)/Communication error alarm/User program indication (Red) Automatically turning off the backlight:

1~99 minutes (0: The backlight is not turned off.) (The life span of the backlight is about 50,000 hours at a temperature of 25°C) Backlight Contrast adjustment Set by software, 10 levels of adjustment ASCII: (Code page 850) Alphanumeric code (including European characters) Taiwan: Traditional Chinese fonts China: Simplified Chinese fonts Language/Font Resolution 192 × 64 dots Display range 101.8 mm (W) × 35.24 mm (H); 4.1” (diagonal) Font size ASCII: 5 × 8, 8 × 8, 8 × 12, 8 × 16 5×8 dots: 38 characters × 8 rows 8×12 dots: 8×8 dots: 24 characters × 8 rows 8×16 dots: 24 characters × 5 rows 24 characters × 4 rows Display text Program Transmission method: Virtual communication port Data length:

7 or 8 bits, Stop bits: 1 or 2 bits, Parity: None/Odd/Even Baud rate: 9,600 bps~115,200 bps USB: USB (Type B) terminal upload/download communication port USB (COM1) Extension Asynchronous transmission method: RS-485 Data length: 7 or 8 bits, Stop bits: 1 or 2 bits, Parity: None/Odd/Even Baud rate: 9,600 bps~115,200 bps RS-485: 8 PIN-removable terminal block communication port RS485 (COM2) RS485 (COM3) Download & Monitoring Download program to TP through virtual COM port method Extension interface Slot for a program copy card

Стр. 3

ѓ Electrical Specifications - 3 - Model TP04P series Spec. Panel component Explanation Status 1: When power is ON, LED will start to blink slowly Status 2: When the user-defined conditions are met, LED will blink for one second repeatedly along with an alarm sound. Alarm LED indicator (Red) Power LED indicator When the power is connected to the product, LED will be ON. (Green) Display area LCM display area. It is used to display current program status. 0~9: They function as constants. Users can also define the keys by themselves. Numeric keys Function keys Users can define the keys by themselves If the input value is correct, users can press the key.

Users can define the key in the user page. Enter key Up: increase the value or move up one page. Down: decrease the value or move down one page. Left: Left direction key. Can be used to select the position of the value. Right: Right direction key. Can be used to select the position of the value. Up/Down/Left/Right keys Model TP04P-16TP1R TP04P-32TP1R TP04P-22XA1R TP04P-21EX1R Spec.

CPU LPC1787FBD208 Program memory 1 MB-flash memory RAM of the system 64K Bytes 24VDC (-15% ~ 20%) (With counter-connection protection on the polarity of DC input power) Power supply voltage Power consumption 3.2W 5.2W 4.2W 4.2W Power protection With counter-connection protection on the polarity of DC input power Insulation resistance > 5 MΩ (all I/O point-to-ground insulation resistance: 500 VDC) ESD (IEC 61131-2, IEC 61000-4-2): 8KV Air Discharge EFT (IEC 61131-2, IEC 61000-4-4): Power Line: 2KV, Digital I/O: 1KV, Analog & Communication I/O: 1KV Damped-Oscillatory Wave: Power Line: 1KV, Digital I/O: 1KV RS (IEC 61131-2, IEC 61000-4-3):

26MHz~1GHz, 10V/m Noise immunity The diameter of ground cannot be less than the diameter of the power cable. (If several TP04P are used, they should be grounded directly.) Ground Operating temperature 0°C~50°C: Relative humidity:

20%-90% RH (non-condensing) for hardware Storage temperature -20°C~60°C for hardware Waterproof class of the IP66/NEMA4 front panel Vibration/Shock International standards IEC61131-2, IEC 68-2-6 (TEST Fc)/ IEC61131-2 & IEC 68-2-27 (TEST Ea) resistance Weight 420g 444g 432g 432g Dimensions 175.8 × 108.6 × 59.2 mm (Width(W) × Height(H) × Deep(D)) Cooling method Natural air cooling Mode l Input terminal Item 24VDC (-15% ~ 20%) single common terminal Input number X0, X1 X2~X7, X10~X17 Input type DC (Sinking or sourcing) Input voltage (±10%) 24VDC, 5mA Input impedance 4.7k ohm Maximum frequency 10KHz 60Hz OffOn > 16.5 VDC Action level OnOff Response OffOn 10ms time OnOff

Стр. 4

#1: Life curves 1,000 2,000 3,000 Operation(X10 ) 3 200 300 500 100 30 50 20 *: The specifications for voltage output/voltage input is only applicable to TP04P-22XA1R.

- 4 - Model Output terminal Item Relay Voltage specifications 250VAC, Current Resistive 1.5A /1 point (5A/COM) specifications Inductive #1 Bulb 20WDC/100WAC Response time Approximately 10 ms OffOn 120V AC R esis tive ms) cosψ=0.4) 30VD C In duct ive(t=7 ms) 24 0VA C Ind uctive( cosψ=0.4) 12 0VA C Induc tive(cosψ=0.4) Contact 30 Ind VDC uctive ( t=40m s) 0.1 0.2 0.3 0.5 0.7 1 2 Current(A) Figure 6 Model Specifications for the analog input/output of Item TP04P-22XA1R/TP04P-21EX1R Voltage input* Current input Voltage output* Current output ±10V 22XA1R: ±20mA 21EX1R: 0~20mA -- -- Analog input range Analog output -- -- ±10V 0~20mA range Digital conversion ±2000 22XA1R: ±1000 21EX1R:

0~4000 ±2000 22XA1R: 0~4000 21EX1R: 0~4000 range 12 bits (1LSB=5mV) 22XA1R: 11 bits (1LSB=20uA) 21EX1R: 12 bits (1LSB=5uA) 12 bits (1LSB=5mV) 12 bits (1LSB=5uA) Resolution Input impedance 1MΩ 250Ω -- -- Output impedance -- -- 100Ω Overall accuracy 25°C/77°F: The error is ±0.5% of the input within the range 0~55°C/32~131°F: The error is ±1% of the input within the range Response time 3ms/Channel Isolation None -- Absolute Input ±15V 22XA1R: ±32mA 21EX1R: 0~32mA -- -- range Digital data format Two's complement of a 16-bit number 11 bits are significant bits.

Maximum current -- 10mA (1KΩ~2MΩ) 0~500Ω output (Load allowed) -- The voltage output is equipped with a short circuit protection and the overcurrent protection. (If the voltage output is short-circuited for a long time, it may be damaged.) The current output can be an open circuit. Protection Model TP04P-21EX1R Item Specifications for temperature measurement Sensor type 2-wire/3-wire PT100 Driving current 1.6mA Temperature input -20°C~160°C range