Delta Electronics — 6.27.2 Explanation of CANopen Communication Instructions

Chapter 6 Applied Instructions 5. The following list shows the settings to initialize a servo drive in the AS Series. A. Set P2-30 (auxiliary function) to 5 to indicate that the servo does not need to store the settings in EEPROM permanently. This can prolong the servo life span. B. Reset P6-02 (PATH#1) to 0 and P6-06 (PATH#3) to 0. This indicates that PATH#1 & #3 in PR mode are both cleared. C. Set P3-06 (SDI source) to 16#0100. This indicates that DI1–DI8 are controlled by the hardware, EDI9 is controlled by the software, and EDI10–EDI14 are controlled by the hardware. D. Reset P4-07 (SDI status controlled manually) to 0. E. Set P2-36 (EDI9) to 16#0101.

This indicates that the function of EDI9 is set to Servo ON. F. Set P0-17 (CM1A) to 1. This indicates that the mapping parameter is the pulse command output register CMD_O. G. Set P0-18 (CM2A) to 64. This indicates that the mapping parameter is the pulse command register CMD_E. H. Set P5-20–P5-35 (acceleration time) to 1. This indicates that the acceleration time is 1 ms. I. Set P5-60–P5-75 (target speed) to 1. This indicates that the target speed is 0.1 rpm. J. Set PDO1 to correspond to P5-07 (PR command), P0-01 (Fault code), P0-46 (state of DO point) and P4-07 (state of DI point) K. Set PDO2 to correspond to P0-09 (CM1 state: CMD_O) and P0-10 (CM2 state: CMD_E). 6_ L.

Set PDO3 to correspond to P0-11 (CM3 state: state of current torque) M. Available for PLC with FW V1.04.00 or later: set time for the heartbeat and the PLC scan overtime to 200ms (default). When a communication overtime occurs, PLC will send error message (error LED flashing slowly; refer to error code for more details) and the servo turns off automatically. N. If SM1685 is ON, PDO3 reads self-defined parameters from servo drive P0-12 and stores the data in SR791-SR806. You need to set up the P0-20 (CM4A) before executing. 2 SRs are reserved for every servo drive axis and you can define their data types. Note:

PLC with firmware V1.04.10 or later supports states of current torque (PD03) and DI point (PD01). PLC with firmware V.104.60 or later supports reading self-defined parameters (PD03) 6. Do not use the COPRW instruction (API 2807) to modify the servo parameters of the eight items A, B, F, G, J, K and N above after initialization. 7. When you use an absolute-type servo, use the COPRW communication instruction to write 16#0100 to P3-12, which writes the relevant absolute-type servo parameters to EEPROM at the moment the servo powers off. 6-897