Yanmar — Yanmar Electronic Control System Manual (EN)

3 i5601E Digital Display calibration Trolling Menu “Back” returns to Main Menu. Before doing so, the system will check to see if any settings were changed and need to be saved. If changes exist, the “Save Settings” screen will appear. Save Settings Note: Troling calibration should be performed in full Trolling Mode. Troll Mode Must have Trolling enabled or present to allow choices. Setting Trolling to "NONE" will disable Trolling. Lever - Throttle Lever Action in Trolling Mode This is displayed only if the trolling mode is set for "SPLIT". This specifies the percentage of lever travel allocated between trolling and throttle. The percentage (20-80) represents the dividing point.

For example a value of 50 would divide the lever equally between troll (the first 50%) and throttle (the last 50%). © 2011 Yanmar Marine International • Rev. 2.0 Yanmar Electronic Control Systems Technical Manual 3:37 Display Description Default Setting BY2 Unlimited 6LY3 SY GEN III Troll Mode SPLIT X Lever 60 X Max Throttle (in Troll Mode) 40 X Valve Cal n/a X Menu Item Display Choice Status Lever action Troll Mode NONE No Trolling FULL Entire throttle travel dedicated to Trolling SPLIT Split between Trolling and Engine Throttle Menu Item Display Choice Function Lever 20 20% Min to Increments at 10% 80 80% Max