Yanmar — Indicators and Alarms (Optional)

PRODUCT OVERVIEW 12/05 Setup Screen Access and Control (Setting the engine speed pulse value for B20/C30 type panel) Use the buttons on the bottom of the LCD display to set the instrument panel. Press the left button to switch between displays. Figure 2 Press and hold both buttons until “SET UP” appears. Press the left button and go to the screen “UNIT”. Press the left button and go to the next screen “ENGINE”. Confirm that the display says “ENGINE”. Press the right button and “P****” appears. Note: The pre-set value of speed pulse is indicated on the box of each panel. Next, press the left button and select the speed pulse value for each engine model.

YM with VALEO alternator 12.10 After confirming the value is changed correctly, press the right button to return to the “ENGINE” screen. Press the left button again to go from the “ENGINE” screen to the “EXIT” screen. After confirming the display, press the right button to re-start the panel and return to the hourmeter display. Figure 12 YM Series Operation Manual 21 1 2 Scroll 3 Select Engine type select 4 5 Scroll 7 6 Select Exit setup Return to LCD control 8 043719-02EN03 Engine model Speed pulse value YM with HITACHI alternator 10.29