John Deere 450DLC — Main Controller (MCF) Circuit Theory of Operation

TM2361 (24JUN08) 9015-15-31 450DLC Excavator Operation and Tests 062608 PN=475 Sub-System Diagnostics MCF inputs involved: The MCF continually compares signals from the pump control pressure sensors to signals from the pump • Pump 1 delivery pressure sensor (B35) delivery pressure sensors. • Arm in pressure sensor (B51) • Boom up pressure sensor (B52) When the counterweight control lever is moved to the raise or lower position, counterweight pressure sensor MCF output involved: Power dig solenoid (Y24) (B46) detects pilot pressure and sends a corresponding signal to terminal D3 on the MCF.

The auto-power lift control has the following When the MCF receives this signal, it activates power requirements: dig solenoid (Y24) to increase main relief pressure. • Boom up function operated [pressure detected by At the same time, the MCF decreases current to pump boom up pressure sensor (B52) (terminal C13) more control solenoids (Y12 and Y13), causing pump than 1700 kPa (17 bar) (247 psi)] displacement (and pump delivery flow rate) to go to • Arm in function not operated [pressure detected by minimum. arm in pressure sensor (B51) (terminal C23) less than 500 kPa (5 bar) (73 psi) Travel Speed Solenoid (Y25) (SI):

Selects travel mode • High pressure detected by pump 1 delivery pressure by changing the swash plate angle on the travel sensor (B35) (terminal C3) 29 100 kPa (291 bar) motors. (4220 psi) MCF input involved: Travel speed switch (S11) Counterweight Removal and Installation Control— Temporarily energizes the power dig solenoid and MCF output involved: Travel speed solenoid (Y25) controls pump delivery flow rate during the counterweight remove and install process. Slow speed— When travel speed switch (S11) is at the LOW (turtle) position, no ground is sent to terminal MCF inputs involved: B21 on the MCF.

When the MCF does not detect ground at terminal B21, the MCF de-energizes travel • Counterweight removal pressure sensor (B46) speed solenoid (Y25). • Pump 1 control pressure sensor (B36) • Pump 2 control pressure sensor (B38) Fast speed— When travel speed switch (S11) is at the HI (rabbit) position, the switch provides a ground to MCF outputs involved: terminal B21 on the MCF. When the MCF detects this ground, it sends current out terminals A11 and A17 to • Power dig solenoid (Y24) travel speed solenoid (Y25), energizing the solenoid. • Pump 1 control solenoid (Y12) • Pump 2 control solenoid (Y13) For hydraulic information on this circuit, see Travel Motor Speed Circuit Operation.

(Group 9025-05.) The MCF determines the actual swash plate angle from signals received from pump control pressure Reversing Fan Solenoids (Y8 and Y9): The reversing sensors (B36 and B38) (terminals D11 and D4). The fan operation requires that the pilot shut off lever be in MCF determines the target swash plate angle from the rearward (LOCK) position and the air conditioning signals received from pump delivery pressure sensors OFF. The process takes approximately 100 seconds (B35 and B37) (terminals C3 and C12). from beginning to end. Continued on next page CS33148,00008EB –19–28APR06–14/15 9015 15 31