John Deere 450DLC — Boom Flow Rate (port SF) Test and Adjustment

TM2361 (24JUN08) 9025-25-30 450DLC Excavator Operation and Tests 062608 PN=890 Tests NOTE: The calculated pressure reading for boom flow rate solenoid valve does not display on the monitor in cab. Use the or Dr. ZX application. 5. Warm hydraulic oil to specification. See Hydraulic Oil Warm-Up Procedure. (Group 9025-25.) Specification Hydraulic Oil—Temperature........................................................ 45—55°C 110—130°F 6. Run machine at specification. Specification Engine—Speed............................................................................ Fast Idle Work Mode Switch—Position......................................................

Dig Mode Power Mode Switch—Position.............................. HP (High Power) Mode Auto Idle Switch—Position.................................................................. OFF 7. Actuate boom down function in combined operation with arm in. 8. Calculate the pressure range using calculated reading from the monitor and specify tolerance. Check that the actual reading from gauge is within the pressure range. Specification Boom Flow Rate Solenoid Valve (port SF)—Pressure.......................................

Monitor Reading ± 0.2 MPa Monitor Reading ± 200 kPa Monitor Reading ± 2.0 bar Monitor Reading ± 29.0 psi 9025 25 30 Actual gauge reading must be within the pressure range Example of Calculated Reading Actuated Neutral Example of 3.92 MPa 0.0 MPa Calculated Reading 3920 kPa 00 kPa 39.2 bar 0.0 bar 568 psi 00 psi Continued on next page LD30992,00002AF –19–25MAY06–3/4 Example of Calculated Reading Actuated Neutral Example of Calculated Reading 3.92 MPa 3920 kPa 39.2 bar 568 psi 0.0 MPa 00 kPa 0.0 bar 00 psi