CliQ II DIN Rail Power Supply 24V 60W 1Phase Features RoHS Compliant Efficiency > 89% Typ. Over load protection Over voltage protection Meet Energy Star Level V Over temperature protection Expected life time : 10 Years Power boost 150% for 5 seconds Output terminals for fast wiring and easy installation Compact design for easy handling With Conformal Coating (Class1 Div 2 Hazard Loc Ready) Model No. DRP 024V 060W 1BA Weight: 0.37Kg. Size: 121 mm X 32 mm X 125 mm (H x W x D) Redundancy : DRR-20A & DRR-40A External ORing Diode Description The new CliQ II DRP024V060W1BA is the latest offering from one of the World’s No.1 Power Supply Company.

The product offers a nominal output voltage of 24V, a wide temperature range from -20°C to 80°C and a minimum holdup time of >20ms@115Vac.The state-of-the-art design is made to withstand harsh industrial environments. The rugged, compact design aluminium case is shock and vibration resistant according to IEC60068-2-6. The 60 watts CliQ II DIN Rail power supply provides over voltage, overload and thermal protection. Due to the wide input voltage range from 85 to 264Vac, the Delta’s CliQ power supply is worldwide usable.

www.DeltaPSU.com 1 INPUT SPECIFICATION Input Voltage (Nominal) 100 - 240Vac Input Voltage range 85 - 264Vac Input Frequency (Nominal) 50 - 60Hz Input Frequency range 47 - 63Hz DC Input Voltage (Nominal) 125 - 250Vdc DC Input Voltage Range 120 - 375Vdc Input Current Efficiency > 89.0% @ 115Vac & 230Vac Inrush current (Cold Start) Leakage Current Energy Star Meet Level V OUTPUT SPECIFICATION Output Voltage (Nominal) 24 Vdc Output Voltage Tolerance +/- 2% (Initial set point tolerance) Output Voltage Adjust Range 24 – 28 Vdc Line Regulation Load Regulation Ripple & Noise (PARD), 20MHz BW Output Current (Nominal) 2.5 A Power Derating above 50°C Derated Linearly 2.5% / °C Rise Time Start-Up Time Hold-Up Time > 20ms @ 115Vac, > 125ms @ 230Vac (100% load, 25°C) Dynamic Response (Overshoot & +/-5% @ 0% - 100% load Undershoot O/P Voltage) Startup with capacitive loads 8,000µF @ nominal input & nominal O/P voltage 24V (25°C)

Стр. 1

CliQ II DIN Rail Power Supply 24V 60W 1Phase Device Description: 1) Input terminal block connector 2) Output terminal block connector 3) DC voltage adjustment potentiometer 4) DC OK control LED (green) 5) Universal mounting rail system Mechanical Drawing: www.DeltaPSU.com 2 MECHANICAL SPECIFICATION Dimension 121 mm X 32 mm X 125 mm (H x W x D) Weight 0.37kg Cooling System Convection Input Terminal Pluggable connector 3 pin (Rated 300V/15A) Output Terminal Pluggable connector 2 pin (Rated 300V/15A) Indicator Green LED (DC OK) Casing Aluminum

Стр. 2

CliQ II DIN Rail Power Supply 24V 60W 1Phase Block Diagram: PRIMARY www.DeltaPSU.com 3

Стр. 3

CliQ II DIN Rail Power Supply 24V 60W 1Phase Over Load Protection Over Voltage Protection The Power Supply is provided with an overload The Power Supply has an overvoltage protection (OVP) protection (OLP/OCP) function which protects the power and is activated when the power supply feedback supply from possible damage caused by excess current. The Power Supply also has an over temperature circuit fails. The output voltage will not be > 32V +10%/- 10%, under any Line/Load and operating ambient protection (OTP) in case overload condition persists for temperature.

The Power Supply does not shut down an extended duration and is below the overload trigger but goes into Hiccup mode (Auto-Recovery). The point but > 100% load Typically the overload current (I OL ) is > I SURGE (150%) output voltage will start dropping when output voltage will recover back to 24VDC once the fault is removed. the power supply reaches max power limit. It will go into Short Circuit Protection bouncing mode when the output reaches UVLO (under voltage point).

The output voltage will recover The Power Supply has a short circuit protection which automatically when the overload condition is removed is in line with the overload protection and activates Over Temperature Protection whenever there is a short across the output voltage. It will go into bouncing mode and recovers automatically The Power Supply has an over temperature protection (OTP). This is activated when the overload condition when the fault is removed. persists for an extended duration and the output current is below the overload trigger point but >100% load.

In the event of a higher ambient operating condition at 100% load, the Power Supply will run into OTP when the ambient temperature is > 80°C. When activated, the output voltage will go into bouncing mode until the operating ambient temperature drops to 50°C or output capacity is reduced as recommended in the graph. www.DeltaPSU.com 5 PROTECTION 32V +10%/-10%, SELV output, Hicc-up Mode, Non-Latching Over Voltage Protection (Auto recovery). > 150% of rated load current, Hicc-up Mode, Non-Latching Over Load, Over Current Protection (Auto recovery). Over Temperature Protection recovery). Hicc-up Mode, Non-Latching, (Auto-recovery when the fault is Short Circuit Protection removed).