sinee — EM303B User Manual (EN)

User Manual EM303B General Purpose Inverter 53 No. Function Range Unit Default Type S/N Drive Control Mode 0: V/F open loop Control 1: Not used 2: SVC0 3: SVC1 2 〇 2 F0-02 Reference Input Control Mode 0: Speed input 1: Torque input(F0-02=3 ) 0 〇 3 F0-03 Start/Stop Control Options 0: Keypad 1: Terminal 2: RS485 0 〇 4 F0-04 Terminal Start/Stop Control Options 0: RUN-Run, F/R-Forward/Reverse 1: RUN-Forward, F/R- Reverse 2: RUN-NO forward, Xi-NC stop, F/R-NO reverse 3: RUN-NO run, Xi-NC stop, F/R- Forward/Reverse 0 〇 5 F0-05 Regular Speed Setting Mode 0: Primary Numeric Frequency 1: VP 2: VS 3: IS 4: Not Used 5: K3*VS+K4*IS 6: K3*VS+K5*VF 7: K4*IS+K6*IF 8: MAX{K3*VS,K5*VF} 9:

MAX{K4*IS,K6*IF} 10: K1*VP+K2*(K3*VS+K4*IS+ K5*VF+K6*IF-K8*5V) 1 〇 6 F0-06 Primary Numeric Frequency Setting 0.00~Fmax Hz 0.00 ● 7 F0-07 Motor Running Direction 0: Forward 1: Reverse 0 ● 8 F0-08 F0-09 Acceleration Time 1 0.00~600.00 S/min 15.00 ● 9 F0-10 Deceleration Time 1 0.00~600.00 S/min 15.00 ● 10 F0-11 Jog Numeric Frequency 0.00~Fmax/0.0~Fmax Hz 5.00 ● 11 F0-12 Jog Acceleration Time 0.00~600.00 S/min 15.00 ● 12 F0-13 Jog Deceleration Time 0.00~600.00 S/min 15.00 ● 13 Carrier Frequency 0kW~9kW:1.000~16.000 9kW~37kW:1.000~8.000 37kW~110kW:1.000~4.000 110kW~400kW:1.000~3.000 kHz 2.000 ● 14 F0-14