User Manual EM303B General Purpose Inverter 54 No. Function Range Unit Default Type S/N Torque Boost 0: Automatic torque boost 1~10: Fixed torque boost curve 11~20: Oil pump motor boost curve 21~30: Synchronous motor boost curve 31~34: Blower/water pump boost curve 35: Customer defined V/F curve scaling 35 ● 15 F0-15 F0-16 Maximum Frequency Fmax:20.00~600.00 Hz 50.00 〇 16 F0-17 Upper Limit Frequency Fup: Fdown~Fmax Hz 50.00 〇 17 F0-18 Lower Limit Frequency Fdown: 0.00~Fup Hz 0.00 〇 18 Start Mode Options 0: Normal start 1: Speed search start 0 〇 19 F0-19 Stop Mode Options 0: Ramp to stop 1: Coast to stop 0 〇 20 F0-20 JOG +/- Function Setting 0: Jog running 1:
Positive/Negative input switching 2: Disabled 0 〇 21 F0-21 Speed Monitoring Options 0: Frequency Hz 1: Speed rpm 0 ● 22 F0-22 F0-23 Customer Defined Scaling 0.01~600.00 30.00 ● 23 Forward/Reverse Control Mode 0: Reverse Permitted 1: Reverse Prohibited 0 〇 24 F0-24 F0-25 F/R Deadband Time 0.00~600.00 S 0.00 〇 25 Primary Speed Setting Mode 0: Regular speed setting mode 1: Special speed setting mode 2: Process PID input mode 0 〇 26 F0-26 Menu Mode Options 0: Basic menu mode 1: Advanced menu mode 0 〇 27 F0-27 Default Control 0: Disabled 1: Defaults Reset 0 〇 28 F0-28 Parameter Setting Control 0: Parameter setting permitted 1: Parameter lock 0 2: Parameter lock 1 0 〇 29 F0-29 Inverter Model 0:
Model G 1: Model P 0 〇 30 F0-30 F0-31 User Password 0~65535 XXXXX 〇 31