User Manual EM303B General Purpose Inverter 7.1.6 FA Group: Advanced Parameters of Vector Control 74 Gain Speed Search Mode of Software 0: Maximum frequency 1: Stop frequency 2: Setting frequency 0 〇 316 F9-28 F9-29 Not Used 317 No. Function Range Unit Default Type S/N Undervoltage Detection Scale 0.00~100.00(Udc e) _ % 65.18 〇 318 F9-30 Undervoltage Detection Time 0.00~30.00 S 0.50 〇 319 F9-31 No. Function Range Unit Default Type S/N FA-00 Not Used 320 ~ 325 ~ FA-05 Regular Torque Options 0: Regular torque input 1: VS* Regular torque input 2: VF* Regular torque input 3: IS* Regular torque input 4:
IF* Regular torque input 0 〇 326 FA-06 FA-07 Preset Current Limit 1 0.00~180.00 % 150.00 〇 327 FA-08 Preset Current Limit 2 0.00~180.00 % 150.00 〇 328 FA-09 Preset Current Limit 3 0.00~180.00 % 150.00 〇 329 FA-10 Preset Current Limit 4 0.00~180.00 % 150.00 〇 330 FA-11 Preset Current Limit 5 0.00~180.00 % 150.00 〇 331 FA-12 Preset Current Limit 6 0.00~180.00 % 150.00 〇 332 FA-13 Preset Current Limit 7 0.00~180.00 % 150.00 〇 334 FA-14 Motor 2 Rated Power 0.40~480.00 kW XXXX 〇 335 FA-15 Motor 2 Rated Voltage 60~660 V XXX 〇 336 FA-16 Motor 2 Rated Current 0.1~1500.0 A XXXX 〇 337 FA-17 Motor 2 Rated Frequency 20.00~600.00/20.0~6000.0 Hz XXXX 〇 338 FA-18 Motor 2 Rated Speed 1~60000 rpm XXXX 〇 339 FA-19 Motor 2 Wiring Mode 0:Y , 1:Δ X 〇 340 FA-20 Motor 2 Rated Power Factor 0.50~0.99 X 〇 341 Motor 2 Idling Excitation Current I0 0.1~1500.0 A XXXX 〇 342 FA-21 FA-22 Motor 2 Rated Torque Current 0.1~1500.0 A XXXX × 343 Motor 2 Stator Resistance R1 0.01~60.000 Ω XXXX 〇 344 FA-23