sinee — EM303B User Manual (EN)

User Manual EM303B General Purpose Inverter 76 Range Energy Saving Delay Start Time 0.01~60.00 S 0.50 〇 397 FC-13 Energy Saving Permitted Range 60.00~100.00 % 80.00 〇 398 FC-14 FC-15 Output Voltage 0.00~100.00 % 100.00 ● 399 FC-16 Brake Duty Ratio 5.00~100.00 % 80.00 〇 400 No. Function Range Unit Default Type S/N Over-modulation Coefficient 1.00~1.10 1.05 ● 401 FC-17 Voltage Control Ones place: AVR control 0: Disabled 1: Enabled 2: Auto-AVR Tens place: AVR limit control 0: Limit disabled 1: Limit enabled Hundreds place: Not used 001 〇 402 FC-18 Overvoltage Protection Control Ones place: Not Used Tens Place: Dynamic brake options 0: Braking resistor disabled 1:

Braking resistor is enabled in operation 2: Braking resistor is enabledat power-on Hundreds place: Not Used Thousands place: Voltage stall protection mode 0.Void 1.Under voltage stall effective 2.Over voltage stall effective 3.Both under voltage stall and over voltage stall effective 2000 〇 403 FC-19 Voltage at Overvoltage Stall 120.00~140.00 % 130.00 〇 404 FC-20 Overcurrent Stall Proportion Gain IKp 0.00~100.00 0.10 〇 405 FC-21 Overvoltage Stall Proportion Gain VKp 0.00~100.00 3.00 〇 406 FC-22 Overvoltage Integral Time VTi 0.000~10.000, 0.000: No integration S 0.300 〇 407 FC-23 Fault Retry Control Ones place: Fault retry times 0: Fault retry prohibited 1~3:

Fault retry for 1, 2, and 3 times 4: Unlimited fault retry Tens place: In fault retry, fault output terminals will be 0: Off 1: On 00 〇 408 FC-24 FC-25 Fault Retry Timelag 0.01~30.00 S 0.50 〇 409 FC-26 No Fault Timelag 0.01~30.00 S 10.00 〇 410