User Manual EM303B General Purpose Inverter 7.1.10 FE Group: User Defined Terminal Function Parameters 78 Fd-19 435 Fd-20 CPUB Software Version X.XX X.XX X 436 Fd-21 Inverter Rated Power 0.40~480.00 kW XXXX X 437 Fd-22 Inverter Rated Voltage 60~660 V XXX X 438 Fd-23 Inverter Rated Current 0.1~1500.0 A XXXX X 439 Fd-24 Inverter Running Time User monitoring HOUR XXXX X 440 Fd-25 Inverter Running Time User monitoring min XXXX X 441 No.

Function Range Unit Default Type S/N Running Time Control 0:Disabled 1:Enabled 0 - 442 Fd-26 Fd-27 Set Running Time 0~65535 HOUR 0 - 443 Fd-28 Distributor Password 444 Fd-29 Manufacturer Password 445 Fd-30 Keypad Software Version X.XX X.XX X 446 Fd-31 CPUA Software Version X.XX X.XX X 447 No. Function Range Unit Default Type S/N FE-00 Numeric Input Filter Times 0~100; 1=0.50mS 10 〇 448 Terminal Input Positive/Negative Logic X7 X6 X5 X4 X3 X2 X1 0000000 0 〇 449 0 0 0 0 0 0 0 FE-01 0: Positive Logic. On at 0V/Off at 24V 1: Negative Logic.

Off at 0V/ On at 24V FE-02 X1 Input Delay Time 0.00~300.00 S 0.00 〇 450 FE-03 X2 Input Delay Time 0.00~300.00 S 0.00 〇 451 Analog Input Signal Options Ones place: VS input signal options 0: Analog signal input 1: Numeric signal input Tens place: IS input signal options 0: Analog signal input 1: Numeric signal input Hundreds place: VF input signal options 0: Analog signal input 1: Numeric signal input Thousands place: IF input signal options 0: Analog signal input 1: Numeric signal input 0000 〇 452 FE-04 Analog Terminal Input Logic Ones place: Input terminal VS 0:VS is on at high level input 1:VS is onat low level input Tens place:

Input terminal IS 0:IS is on at high level input 1:IS is on at low level input Hundreds place: Input terminal VF 0000 〇 453 FE-05