User Manual EM303B General Purpose Inverter 79 0:VF is on at high level input 1:VF is on at low level input Thousands place: Input terminal IF 0: IF is on at high level input 1: IF is onat low level input Output Signal Type Ones place: Y1 output type 0: Level signal 1: Pulse signal Tens place: Y2 output type 0: Level signal 1: Pulse signal Hundreds place: R1 output type 0: Level signal 1: Pulse signal 000 〇 454 FE-06 Terminal Output Logic Options Ones place: Y1 output logic options 0: Positive logic 1: Negative logic Tens place: Y2 output logic options 0: Positive logic 1: Negative logic Hundreds place: R1 output logic options 0: Positive logic 1:
Negative logic 000 〇 455 FE-07 Virtual Terminal Options Ones place: Terminals Y1/Y2/R1 0: Actual output terminal 1: Virtual output terminal Tens place: Multi-function Input Terminal Xi 0: Actual output terminal 1: Virtual output terminal Hundreds place: Numeric terminal VS/IS/VF/IF 0: Actual output terminal 1:
Virtual output terminal 000 〇 456 FE-08 FE-09 Terminal Y1 Delay Time 0.0~600.0 S 0.0 〇 457 FE-10 Terminal Y1 Pulse Width 0.0~600.0 S 5.0 〇 458 FE-11 Terminal Y2 Delay Time 0.0~600.0 S 0.0 〇 459 FE-12 Terminal Y2 Pulse Width 0.0~600.0 S 5.0 〇 460 FE-13 Terminal R1Delay Time 0.0~600.0 S 0.0 〇 461 FE-14 Terminal R1 Pulse Width 0.0~600.0 S 5.0 〇 462 FE-15 Not Used 463 ~ 467 ~ FE-19 SC and EMC Faults Display 0:SC Drive failure 1:EMC Environment failure 0 X 468 FE-20 FE-21 SlU and SOFT Faults Display 0:SlU Stable undervoltage fault 0 X 469