Cover

EMC filters 3-line filters for converters and power electronics Series/Type: B84143A*R105 Date: May 2014 © EPCOS AG 2015. Reproduction, publication and dissemination of this publication, enclosures hereto and the information contained therein without EPCOS' prior express consent is prohibited. EPCOS AG is a TDK Group Company.

Стр. 1

Cover

3-line filters B84143A*R105 for converters and power electronics Power line filters for 3-phase systems Rated voltage V R : 520/300 V AC Rated current I R : 8 A to 150 A Construction 3-line filters Metal case Features Book size Very good price/performance ratio Ultra-compact design Low weight Easy to install Optimized for long motor cables and operation under full load ENEC, UL and cUL approval Typical applications Frequency converters for motor drives, e.g.  elevators  pumps  traction systems  HVAC systems (heating, ventilation and air Power supplies conditioning) Terminals Finger-safe terminal blocks Marking Marking on component:

Manufacturer's logo, ordering code, rated voltage, rated current, rated temperature, climatic category, date code, approvals Minimum data on packaging: Manufacturer's logo, ordering code, quantity, date code Page 2 of 16 Please read Cautions and warnings and Important notes at the end of this document.

Стр. 2

Cover

3-line filters B84143A*R105 for converters and power electronics Typical circuit diagram Technical data and measuring conditions Page 3 of 16 Please read Cautions and warnings and Important notes at the end of this document. Rated voltage V R 520/300 V AC (50/60 Hz) Rated voltage for IT mains supply Filters 8 A ... 16 A: Up to 420/240 V AC (50/60 Hz) Filters 25 A ... 150 A: Up to 440/255 V AC (50/60 Hz) See also chapter "General technical information", section 7.

Rated current I R Referred to 40 °C rated temperature Test voltage V test 2240 V DC, 2 s (line/line) 2720 V DC, 2 s (lines/case) Overload capability (thermal) 1.5  I for 3 min per hour or R 2.5  I for 30 s per hour R Leakage current l LK At V and 50 Hz R Climatic category (IEC 60068-1) 25/100/21 (25 °C/+100 °C/21 days damp heat test) Approvals IEC 60939, UL 1283, CSA C22.2 No.8

Стр. 3

Cover

3-line filters B84143A*R105 for converters and power electronics Characteristics and ordering codes I A V Ч = Approval granted Dimensional drawings B84143A0008R105 (8 A) General tolerances according to ISO 2768  cL Dimensions in mm Page 4 of 16 Please read Cautions and warnings and Important notes at the end of this document. T c erminal I ross section mm2 LK mA R App typ wei mΩ kg rox.

Ordering code ght Approvals = 520/300 V AC R 8 16 25 36 1 50 1 66 1 90 3 20 3 50 5 4 4 4 0 0 6 5 5 0 4.1 4.1 4.7 4.7 4.7 4.7 5.0 5.0 5.0 16 0.58 9 0.90 5 1.10 4 1.75 2 1.75 1.5 2.7 1.1 4.2 0.90 4.9 0.55 5.3 B84143A0008R105 B84143A0016R105 B84143A0025R105 B84143A0036R105 B84143A0050R105 B84143A0066R105 B84143A0090R105 B84143A0120R105 B84143A0150R105 × × × × × × × × × × × × × × × × × × × × × × × × × × ×

Стр. 4