Delta · 16 стр.

Руководство по эксплуатации фильтров EPCOS B84143A*R107 (EN)

Оригинальное название: EMC filters, 3-line filters for converters and power electronics - B84143A*R107

Читать онлайн

Похожие инструкции

Текст документа

EMC filters 3-line filters for converters and power electronics Series/Type: B84143A*R107 Date: July 2016 © EPCOS AG 2016. Reproduction, publication and dissemination of this publication, enclosures hereto and the information contained therein without EPCOS' prior express consent is prohibited. EPCOS AG is a TDK Group Company.

Стр. 1

3-line filters B84143A*R107 for converters and power electronics Power line filters for 3-phase systems Rated voltage V R : 520/300 V AC Rated current I R : 10 A to 100 A Construction 3-line filters Metal case Features High insertion loss Optimized leakage current Easy to install Low weight Compact design Degree of protection: IP 20 1) Optimized for long motor cables and operation under full load ENEC, UL and cUL approval Typical applications Frequency converters for motor drives, e.g.

 elevators  pumps  conveyor systems  HVAC systems (heating, ventilation and air conditioning) Power supplies Textile machines, packaging machines, machine-tools Terminals Finger-safe terminal blocks Marking Marking on component: Manufacturer's logo, ordering code, rated voltage, rated current, rated temperature, climatic category, date code, approvals Minimum data on packaging: Manufacturer's logo, ordering code, quantity, date code 1) According to IEC 60529 Page 2 of 16 Please read Cautions and warnings and Important notes at the end of this document.

Стр. 2

3-line filters B84143A*R107 for converters and power electronics Typical circuit diagram Technical data and measuring conditions Characteristics and ordering codes Ч = Approval granted Page 3 of 16 Please read Cautions and warnings and Important notes at the end of this document.

Rated voltage V R 520/300 V AC (50/60 Hz) Rated current I R Referred to 50 °C rated temperature Test voltage V test 2236 V DC, 2 s (line/line) 2720 V DC, 2 s (lines/case) Overload capability (thermal) 1.5  I for 3 min per hour or R 2.5  I for 30 s per hour R Leakage current l LK At V and 50 Hz R Climatic category (IEC 60068-1) 25/100/21 (25 °C/+100 °C/21 days damp heat test) Approvals IEC 60939, UL 1283, CSA C22.2 No.8 I R A Terminal cross section mm2 I LK mA R typ mΩ Approx.

weight kg Ordering code Approvals V = 520/300 V AC R 10 20 35 50 65 80 100 4 4 10 25 25 25 50 3.1 3.1 3.4 3.4 3.4 3.4 3.4 5.5 3.3 1.7 1.1 0.94 0.60 0.48 0.4 0.6 0.9 1.4 1.9 2.4 2.9 B84143A0010R107 B84143A0020R107 B84143A0035R107 B84143A0050R107 B84143A0065R107 B84143A0080R107 B84143A0100R107 × × × × × × × × × × × × × × × × × × × × ×

Стр. 3

3-line filters B84143A*R107 for converters and power electronics Dimensional drawings B84143A0010R106, B84143A0020R106 (10 A, 20 A) General tolerances according to ISO 2768  cL Dimensions in mm Page 4 of 16 Please read Cautions and warnings and Important notes at the end of this document.

Стр. 4