System Messages - Alphabetical List *Subdirectory list too long* (-546) Explanation: A directory path contains too many subdirectories, or the directory path is too long to be processed. The path is a combination of subdirectories in the file specification and the default directory path set by the DEFAULT monitor command. Directory paths are limited to a total of 16 subdirectories and 80 characters (including any portion of the directory path specified by the current default path). User action: Specify a shorter directory path in the file specification or in the DEFAULT command.
If you are accessing a foreign disk that contains more than 16 nested subdirectories, you cannot read the files in subdirectories nested deeper than 16 levels. In this case, you must use the system that created the disk to copy the files to a directory that is nested less deeply. *Switch can't be enabled* (-314) Explanation: An ENABLE command for a certain switch has been rejected because of some error condition. For example, ENABLE POWER fails if the system is in FATAL ERROR state. User action: Review the description for the switch you are trying to enable, correct the error condition, and try again. *SYSFAIL detected by CPU* (-629) Explanation:
A board on the VMEbus has encountered a severe error and asserted the SYSFAIL signal which turns off HIGH POWER. The watchdog timers on the CPU boards assert this signal and light the SF LED if severe software errors occur. User action: Check the SYSFAIL LEDs on the front edge of the boards. The board which has failed should light its LED. Restart the system. Verify proper seating of the system boards and correct device connections to the boards. Test the system with as many boards removed as possible, adding boards back in until the problem board is identified. If the problem persists, contact Omron Adept Customer Service. *SYSFAIL detected by robot* (-642) Explanation:
The motion interface board has detected a SYSFAIL signal on the VMEbus and has asserted the backplane E-STOP signal. This error is normally superseded by other errors and not seen. User action: Check for a subsequent message. To determine if there was an unreported RSC error, type listr error( task ,4) , where task is the number of the task that received the error. If no additional information is available, call Omron Adept Customer Service. Task = (None) Explanation: The SEE editor DEBUG extended command has been used to initiate a program debugging session for the current program. The debugger needs to know which eV+Language Reference Guide, v2.x, 18319-000 Rev A Page 653